Design
Parameters
Services
Download
DESIGN FEATURES
MATERIALS
OPERATING PARAMETERS
• Capacities up to 2400 (m3/h) (11000 gpm)
• Head up to 1200 (m) (3937 Feet)
• Power through 2237 (kW) (3000 hp)
• Frequency 50/60 Hz
• Temperatures to 300°F (150°C).
SERVICES
• Primary Water Supply – Fresh water or Sea
water
• Mining Processes - Solvent Extraction/
Electro-Winning (SX/EW), Dewatering,
Tailings & Post Processed Solutions
• Oil & Gas Production – Onshore, Offshore
and Pipeline.
Axial Split Case Multistage Pumps (HA)
Split Stage Center Bushing
• Allow dynamic balancing of
assembled rotating element.
• Can be removed for
inspection of wear surfaces
without disassembling rotor
assembly
Hydraulic Crossover
• Minimum friction loss,
maximum efficiency.
• Provides permanent axial
hydraulic balance.
Pumpshaft
• Fully machined and
sized for application
thrust and torque
• Different engineered
alloys for aggressive
applications
Dual Volute Heavy-Duty Casing
• Smoothly transitions fluid
• Assures radial balance for
minimum shaft deflection.
• Discharge connections are in
the lower half casing, allowing
removal of upper half casing
for ease on-site inspection
and/or reparation.
Double Suction First Stage Impeller
• Fully investment casted to
provide smooth passageways
for low-loss fluid flow
• Precisely trimmed and
balanced to reduce vibration
and wear
• Available for low NPSH
service requirements.
Oil-Lubricated Bearing Assembly
• Engineered bearing
arrangements to meet
specified operating
requirements.
• Withstands the total
hydraulic thrust
• Easily replaceable radial
bearing
Single Row Bolting
• All nuts located on top for
ease of maintenance.
Opposed Impeller Arrangement
• Provides permanent axial
hydraulic balance.
IMPELLER ARRANGEMENT
Double suction + 2 impellers in parallel
Double suction + 4 back-to-back impellers.
Automatization, Control & Monitoring
Pump Process Control Software
AUTOMATIZATION, cONTROL & MONITORING
Reduce system operation and maintenance costs while increasing process accuracy and protection. The software provides multiple pump control and protection, as well as system monitoring and protection.
PUMP PROCESS CONTROL SOFTWARE
Pump Genius software monitors system pressure or flow and references low / high set point and run time requirements. The lead and lag pumps are cycled on and off based on motor run times.